perf: 增加故障实例参考描述信息

dev
huangfeng 2 weeks ago
parent eb50d898a4
commit b8462cd08a

@ -19,6 +19,7 @@ public class SanbizhiModel {
Float c2h4_c2h6_value;
String c2h4_c2h6_code;
String status;
String desc;
public boolean build(Map<String, Object> map) {
Iterator<String> it = map.keySet().iterator();
@ -81,19 +82,24 @@ public class SanbizhiModel {
} else if (ch4_h2_code.equals("1")) {
status = "局部放电";
desc = "高湿度,高含气量引起油中低能量密度的局部放电";
} else if (ch4_h2_code.equals("2")) {
status = "低温过热(150-300)C";
desc = "分接开关接触不良,引线夹件螺丝松动或接头焊接不良,涡流引起铜过热,铁心漏磁,局部短路,层间绝缘不良,铁心多点接等";
}
} else if (c2h4_c2h6_code.equals("1")) {
if (ch4_h2_code.equals("0")) {
status = "低温过热(低于150C)";
desc = "绝缘导线过热注意CO和CO₂含量和CO₂/CO值";
} else if (ch4_h2_code.equals("1")) {
} else if (ch4_h2_code.equals("2")) {
status = "中温过热(300-700)C";
desc = "分接开关接触不良,引线夹件螺丝松动或接头焊接不良,涡流引起铜过热,铁心漏磁,局部短路,层间绝缘不良,铁心多点接等";
}
} else if (c2h4_c2h6_code.equals("2")) {
status = "高温过热(高于700C)";
desc = "分接开关接触不良,引线夹件螺丝松动或接头焊接不良,涡流引起铜过热,铁心漏磁,局部短路,层间绝缘不良,铁心多点接等";
}
} else if (c2h2_c2h4_code.equals("1")) {
if (ch4_h2_code.equals("0")) {
@ -103,6 +109,7 @@ public class SanbizhiModel {
} else if (ch4_h2_code.equals("2")) {
status = "低能放电兼过热";
}
desc = "引线对电位未固定的部件之间连续火花放电,分接抽头引线和油膜闪络,不同电位之间的油中火花放电或悬浮电位之间的火花放电";
} else if (c2h2_c2h4_code.equals("2")) {
if (ch4_h2_code.equals("0")) {
status = "电弧放电";
@ -111,6 +118,7 @@ public class SanbizhiModel {
} else if (ch4_h2_code.equals("2")) {
status = "电弧放电兼过热";
}
desc = "线圈匝间、层间短路,相间闪络,分接头引线间油膜闪络,引线对箱壳放电,线圈熔断,分接开关飞弧,因环路电流引起电弧,引线对其他接地体放电等";
}
return true;
}

Loading…
Cancel
Save